Spec #:M24643/36-01UD

MFR #:M24643/36-01UD

GCG #:LS3SWUS3

Spec #:M24643/36-01UD

MFR #:M24643/36-01UD

GCG #:LS3SWUS3

Min Qty:1

  |  

Qty Increment:1

Seacoast USA's M24643/36-01UD (LS3SWUS3) is a 600V watertight cable with non-flexing service. M24643/36-01UD has 9 18 AWG conductors with a minimum diameter of 0.675 and a maximum diameter of 0.71 inches. LS3SWUS3 has a bend radius of 8.5 inches, and is Individually & Double Overall Shielded with Thermoset insulation material and a Cross-Linked Polyolefin external jacket, operating from -20°C to +90°C. Stranded coated or uncoated copper conductor, thermoset insulation, three conductors (white-black-red) cabled to form triad, optional binder tape, braided tinned copper shielded, shielded insulation of two sealed Polyester tapes or one tape with extruded jacket. Standard Identification Code by Method 2. The required number of shielded triads cabled consecutively, fillers, binder tape. Cross-linked Polyolefin jacket. Double overall shielded.
Requires Quote

Min Qty:1

  |  

Qty Increment:1

Seacoast USA's M24643/36-01UD (LS3SWUS3) is a 600V watertight cable with non-flexing service. M24643/36-01UD has 9 18 AWG conductors with a minimum diameter of 0.675 and a maximum diameter of 0.71 inches. LS3SWUS3 has a bend radius of 8.5 inches, and is Individually & Double Overall Shielded with Thermoset insulation material and a Cross-Linked Polyolefin external jacket, operating from -20°C to +90°C. Stranded coated or uncoated copper conductor, thermoset insulation, three conductors (white-black-red) cabled to form triad, optional binder tape, braided tinned copper shielded, shielded insulation of two sealed Polyester tapes or one tape with extruded jacket. Standard Identification Code by Method 2. The required number of shielded triads cabled consecutively, fillers, binder tape. Cross-linked Polyolefin jacket. Double overall shielded.

Attributes

Environmental Properties
Temperature Rating (Range)-20°C to +90°C
General Information
ManufacturerSeacoast
Design & Construction
Conductor Count9
Jacket MaterialCross-Linked Polyolefin
Cable Diameter Max (in)0.71
Solid/StrandedStranded
Shielded/UnshieldedIndividually & Double Overall Shielded
Cable Diameter Min (in)0.675
Electrical Properties
Insulation MaterialThermoset
Voltage Rating600V
Physical Properties
Bend Radius (in)8.5
Weight per Foot0.429