Spec #:M24643/36-01UN

MFR #:M24643/36-01UN

GCG #:LS3SWU3

Spec #:M24643/36-01UN

MFR #:M24643/36-01UN

GCG #:LS3SWU3

Min Qty:1

  |  

Qty Increment:1

Seacoast USA's M24643/36-01UN (LS3SWU3) is a 600V watertight cable with non-flexing service. M24643/36-01UN has 9 18 AWG conductors with a minimum diameter of 0.61 and a maximum diameter of 0.655 inches. LS3SWU3 has a bend radius of 4.5 inches, and is Individually & Overall Shielded with Thermoset insulation material and a Cross-Linked Polyolefin external jacket, operating from -20°C to +90°C. Stranded coated or uncoated copper conductor, thermoset insulation, three conductors (white-black-red) cabled to form triad, optional binder tape, braided tinned copper shielded, shielded insulation of two sealed Polyester tapes or one tape with extruded jacket. Standard Identification Code by Method 2. The required number of shielded triads cabled consecutively, fillers, binder tape. Cross-linked Polyolefin jacket.
Requires Quote

Min Qty:1

  |  

Qty Increment:1

Seacoast USA's M24643/36-01UN (LS3SWU3) is a 600V watertight cable with non-flexing service. M24643/36-01UN has 9 18 AWG conductors with a minimum diameter of 0.61 and a maximum diameter of 0.655 inches. LS3SWU3 has a bend radius of 4.5 inches, and is Individually & Overall Shielded with Thermoset insulation material and a Cross-Linked Polyolefin external jacket, operating from -20°C to +90°C. Stranded coated or uncoated copper conductor, thermoset insulation, three conductors (white-black-red) cabled to form triad, optional binder tape, braided tinned copper shielded, shielded insulation of two sealed Polyester tapes or one tape with extruded jacket. Standard Identification Code by Method 2. The required number of shielded triads cabled consecutively, fillers, binder tape. Cross-linked Polyolefin jacket.

Attributes

Environmental Properties
Temperature Rating (Range)-20°C to +90°C
General Information
ManufacturerSeacoast
Design & Construction
Conductor Count9
Jacket MaterialCross-Linked Polyolefin
Cable Diameter Max (in)0.655
Solid/StrandedStranded
Shielded/UnshieldedIndividually & Overall Shielded
Cable Diameter Min (in)0.61
Electrical Properties
Insulation MaterialThermoset
Voltage Rating600V
Physical Properties
Bend Radius (in)4.5
Weight per Foot0.298