Seacoast USA's M24640/18-04UO (3XSOW14) is a 600V light weight, watertight cable with non-flexing service. M24640/18-04UO has 42 18 AWG conductors in shielded triads with a minimum diameter of 0.898 and a maximum diameter of 0.968 inches. 3XSOW14 has a bend radius of 12 inches, and is Individually & Overall Shielded with Cross-Linked Polyalkene insulation material and a Cross-Linked Polyvinylidene Flouride (PVDF) external jacket, operating from -20°C to +105°C. Multitriad, 7 strand tinned copper conductor, extruded irradiation cross-linked Polyalkene insulation with irradiated crosslinked Polyvinylidene Flouride (PVDF) insulation jacket (conductors per SAE-AS81044). Three conductors twisted to form a triad, optional binder tape, tinned copper braid shied, plus a tape shielded isolation. The required number of triads cabled consecutively, optional binder tape, cross-linked Polyolefin jacket, surface marking. Overall optimized tinned copper braid shielded and optional binder tape. Standard Identification Code by Method 2.
Requires Quote
Min Qty:1
|Qty Increment:1
Seacoast USA's M24640/18-04UO (3XSOW14) is a 600V light weight, watertight cable with non-flexing service. M24640/18-04UO has 42 18 AWG conductors in shielded triads with a minimum diameter of 0.898 and a maximum diameter of 0.968 inches. 3XSOW14 has a bend radius of 12 inches, and is Individually & Overall Shielded with Cross-Linked Polyalkene insulation material and a Cross-Linked Polyvinylidene Flouride (PVDF) external jacket, operating from -20°C to +105°C. Multitriad, 7 strand tinned copper conductor, extruded irradiation cross-linked Polyalkene insulation with irradiated crosslinked Polyvinylidene Flouride (PVDF) insulation jacket (conductors per SAE-AS81044). Three conductors twisted to form a triad, optional binder tape, tinned copper braid shied, plus a tape shielded isolation. The required number of triads cabled consecutively, optional binder tape, cross-linked Polyolefin jacket, surface marking. Overall optimized tinned copper braid shielded and optional binder tape. Standard Identification Code by Method 2.
- Attributes
Attributes
Environmental Properties
Temperature Rating (Range)-20°C to +105°C
General Information
ManufacturerSeacoast
Design & Construction
Conductor MaterialTin-Coated Copper
Conductor Count42
Jacket MaterialCross-Linked Polyvinylidene Flouride (PVDF)
Cable Diameter Max (in)0.968
Solid/StrandedStranded
Stranding7
Shielded/UnshieldedIndividually & Overall Shielded
Shield TypeTape & Tin-Coated Copper Braid
Cable Diameter Min (in)0.898
Electrical Properties
Insulation MaterialCross-Linked Polyalkene
Voltage Rating600V
Physical Properties
Bend Radius (in)12
Weight per Foot0.88