2XSW1
Spec #:M24640/16-01UN
MFR #:M24640/16-01UN
GCG #:2XSW1
Spec #:M24640/16-01UN
MFR #:M24640/16-01UN
GCG #:2XSW1
Min Qty:1
|Qty Increment:1
Seacoast USA's M24640/16-01UN (2XSW1) is a 600V light weight, watertight cable with non-flexing service. M24640/16-01UN has 2 18 AWG conductors with a minimum diameter of 0.24 and a maximum diameter of 0.258 inches. 2XSW1 has a bend radius of 2 inches, and is Individually Shielded with Cross-Linked Polyalkene insulation material and a Cross-Linked Polyvinylidene Flouride (PVDF) external jacket, operating from -20°C to +105°C. Multipair, 7 strand tinned copper conductor, extruded irradiation cross-linked Polyalkene insulation with irradiated cross-linked Polyvinylidene Flouride (PVDF) insulation jacket (conductors per SAE-AS81044). Two conductors twisted to form a pair, tinned copper braid shielded, plus a tape shielded isolation. The required number of pairs cabled consecutively, optional binder tape, cross-linked Polyolefin jacket, surface marking. Standard Identification Code by Method 2.
Requires Quote
Min Qty:1
|Qty Increment:1
Seacoast USA's M24640/16-01UN (2XSW1) is a 600V light weight, watertight cable with non-flexing service. M24640/16-01UN has 2 18 AWG conductors with a minimum diameter of 0.24 and a maximum diameter of 0.258 inches. 2XSW1 has a bend radius of 2 inches, and is Individually Shielded with Cross-Linked Polyalkene insulation material and a Cross-Linked Polyvinylidene Flouride (PVDF) external jacket, operating from -20°C to +105°C. Multipair, 7 strand tinned copper conductor, extruded irradiation cross-linked Polyalkene insulation with irradiated cross-linked Polyvinylidene Flouride (PVDF) insulation jacket (conductors per SAE-AS81044). Two conductors twisted to form a pair, tinned copper braid shielded, plus a tape shielded isolation. The required number of pairs cabled consecutively, optional binder tape, cross-linked Polyolefin jacket, surface marking. Standard Identification Code by Method 2.
- Attributes
Attributes
Environmental Properties
Temperature Rating (Range)-20°C to +105°C
General Information
ManufacturerSeacoast
Design & Construction
Conductor MaterialTin-Coated Copper
Conductor Count2
Jacket MaterialCross-Linked Polyvinylidene Flouride (PVDF)
Cable Diameter Max (in)0.258
Solid/StrandedStranded
Stranding7
Shielded/UnshieldedIndividually Shielded
Shield TypeTape & Tin-Coated Copper Braid
Cable Diameter Min (in)0.24
Electrical Properties
Insulation MaterialCross-Linked Polyalkene
Voltage Rating600V
Physical Properties
Bend Radius (in)2
Weight per Foot0.053