Spec #:M24640/16-04UO

MFR #:M24640/16-04UO

GCG #:2XSOW19

Spec #:M24640/16-04UO

MFR #:M24640/16-04UO

GCG #:2XSOW19

Min Qty:1

  |  

Qty Increment:1

Seacoast USA's M24640/16-04UO (2XSOW19) is a 600V light weight, non-watertight cable with non-flexing service. M24640/16-04UO has 38 18 AWG conductors with a minimum diameter of 0.938 and a maximum diameter of 1.01 inches. 2XSOW19 has a bend radius of inches, and is Individually Shielded with Cross-Linked Polyalkene insulation material and a Cross-Linked Polyvinylidene Flouride (PVDF) external jacket, operating from -20°C to +105°C. Multipair, 7 strand tinned copper conductor, extruded irradiation cross-linked Polyalkene insulation with irradiated cross-linked Polyvinylidene Flouride (PVDF) insulation jacket (conductors per SAE-AS81044). Two conductors twisted to form a pair, tinned copper braid shielded, plus a tape shielded isolation. The required number of pairs cabled consecutively, optional binder tape, cross-linked Polyolefin jacket, surface marking. Standard Identification Code by Method 2.
Requires Quote

Min Qty:1

  |  

Qty Increment:1

Seacoast USA's M24640/16-04UO (2XSOW19) is a 600V light weight, non-watertight cable with non-flexing service. M24640/16-04UO has 38 18 AWG conductors with a minimum diameter of 0.938 and a maximum diameter of 1.01 inches. 2XSOW19 has a bend radius of inches, and is Individually Shielded with Cross-Linked Polyalkene insulation material and a Cross-Linked Polyvinylidene Flouride (PVDF) external jacket, operating from -20°C to +105°C. Multipair, 7 strand tinned copper conductor, extruded irradiation cross-linked Polyalkene insulation with irradiated cross-linked Polyvinylidene Flouride (PVDF) insulation jacket (conductors per SAE-AS81044). Two conductors twisted to form a pair, tinned copper braid shielded, plus a tape shielded isolation. The required number of pairs cabled consecutively, optional binder tape, cross-linked Polyolefin jacket, surface marking. Standard Identification Code by Method 2.

Attributes

Environmental Properties
Temperature Rating (Range)-20°C to +105°C
General Information
ManufacturerSeacoast
Design & Construction
Conductor MaterialTin-Coated Copper
Conductor Count38
Jacket MaterialCross-Linked Polyvinylidene Flouride (PVDF)
Cable Diameter Max (in)1.01
Solid/StrandedStranded
Stranding7
Shielded/UnshieldedIndividually Shielded
Shield TypeTape & Tin-Coated Copper Braid
Cable Diameter Min (in)0.938
Electrical Properties
Insulation MaterialCross-Linked Polyalkene
Voltage Rating600V