Seacoast

Want to stay connected with Seacoast? Sign up for our emails today.

<meta name="google-site-verification" content="3TGVx_bTNjrNhgn43zWfOR7K8hz1G7bglK6OjcYohws" />

Home
0
MY QUOTE{0} items in cart

2XSAW7

2XSAW7

Spec #:M24640/15-02UN

MFR #:M24640/15-02UN

GCG #:2XSAW7

Spec #:M24640/15-02UN

MFR #:M24640/15-02UN

GCG #:2XSAW7

Min Qty:1

  |  

Qty Increment:1

Seacoast USA's M24640/15-02UN (2XSAW7) is a 600V light weight, watertight cable with non-flexing service. M24640/15-02UN has 14 22 AWG conductors with a minimum diameter of 0.461 and a maximum diameter of 0.497 inches. 2XSAW7 has a bend radius of 4 inches, and is Individually Shielded with Cross-Linked Polyalkene insulation material and a Cross-Linked Polyvinylidene Flouride (PVDF) external jacket, operating from -20°C to +105°C. Multipair, 7 strand tinned copper conductor, extruded irradiation cross-linked Polyalkene insulation with irradiated crosslinked Polyvinylidene Flouride (PVDF) insulation jacket (conductors per SAE-AS81044). Two conductors twisted to form a pair, optional binder tape, tinned copper braid shielded, plus a tape shielded isolation. The required number of pairs cabled consecutively, optional binder tape, cross-linked Polyolefin jacket, surface marking. 2XSAWA: Same construction with braided aluminum armor. 2XSAOW: Same construction as 2XSAW with overall optimized tinned copper braid shielded and optional binder tape. Standard Identification Code by Method 2.
Requires Quote

Min Qty:1

  |  

Qty Increment:1

Seacoast USA's M24640/15-02UN (2XSAW7) is a 600V light weight, watertight cable with non-flexing service. M24640/15-02UN has 14 22 AWG conductors with a minimum diameter of 0.461 and a maximum diameter of 0.497 inches. 2XSAW7 has a bend radius of 4 inches, and is Individually Shielded with Cross-Linked Polyalkene insulation material and a Cross-Linked Polyvinylidene Flouride (PVDF) external jacket, operating from -20°C to +105°C. Multipair, 7 strand tinned copper conductor, extruded irradiation cross-linked Polyalkene insulation with irradiated crosslinked Polyvinylidene Flouride (PVDF) insulation jacket (conductors per SAE-AS81044). Two conductors twisted to form a pair, optional binder tape, tinned copper braid shielded, plus a tape shielded isolation. The required number of pairs cabled consecutively, optional binder tape, cross-linked Polyolefin jacket, surface marking. 2XSAWA: Same construction with braided aluminum armor. 2XSAOW: Same construction as 2XSAW with overall optimized tinned copper braid shielded and optional binder tape. Standard Identification Code by Method 2.

Attributes

Environmental Properties
Temperature Rating (Range)-20°C to +105°C
General Information
ManufacturerSeacoast
Design & Construction
Conductor MaterialTin-Coated Copper
Conductor Count14
Jacket MaterialCross-Linked Polyvinylidene Flouride (PVDF)
Cable Diameter Max (in)0.497
Solid/StrandedStranded
Stranding7
Shielded/UnshieldedIndividually Shielded
Shield TypeTape & Tin-Coated Copper Braid
Cable Diameter Min (in)0.461
Electrical Properties
Insulation MaterialCross-Linked Polyalkene
Voltage Rating600V
Physical Properties
Bend Radius (in)4
Weight per Foot0.195