2XOW60
Spec #:M24640/17-05UO
MFR #:M24640/17-05UO
GCG #:2XOW60
Spec #:M24640/17-05UO
MFR #:M24640/17-05UO
GCG #:2XOW60
Min Qty:1
|Qty Increment:1
Seacoast USA's M24640/17-05UO (2XOW60) is a 600V light weight, watertight cable with non-flexing service. M24640/17-05UO has 120 26 AWG conductors with a minimum diameter of 0.744 and a maximum diameter of 0.802 inches. 2XOW60 has a bend radius of 10.5 inches, and is Overall Shielded with Cross-Linked Polyalkene insulation material and a Cross-Linked Polyvinylidene Flouride (PVDF) external jacket, operating from -20°C to +105°C. Multipair, 7 strand tinned copper conductor, extruded irradiation cross-linked Polyalkene insulation with irradiated crosslinked Polyvinylidene Flouride (PVDF) insulation jacket (conductors per SAE-AS81044). Two conductors twisted to form a pair. The required number of pairs cabled consecutively, optional binder tape, overall optimized tinned copper braid shielded, binder tape, cross-linked Polyolefin jacket, surface marking. Pair Identification Code by Method 6 or Telephone Identification Code by Method 3. For 2XOW-77 if Telephone Code, repeat color codes of pairs 1-11, in sequence,for pairs 67-77.
Requires Quote
Min Qty:1
|Qty Increment:1
Seacoast USA's M24640/17-05UO (2XOW60) is a 600V light weight, watertight cable with non-flexing service. M24640/17-05UO has 120 26 AWG conductors with a minimum diameter of 0.744 and a maximum diameter of 0.802 inches. 2XOW60 has a bend radius of 10.5 inches, and is Overall Shielded with Cross-Linked Polyalkene insulation material and a Cross-Linked Polyvinylidene Flouride (PVDF) external jacket, operating from -20°C to +105°C. Multipair, 7 strand tinned copper conductor, extruded irradiation cross-linked Polyalkene insulation with irradiated crosslinked Polyvinylidene Flouride (PVDF) insulation jacket (conductors per SAE-AS81044). Two conductors twisted to form a pair. The required number of pairs cabled consecutively, optional binder tape, overall optimized tinned copper braid shielded, binder tape, cross-linked Polyolefin jacket, surface marking. Pair Identification Code by Method 6 or Telephone Identification Code by Method 3. For 2XOW-77 if Telephone Code, repeat color codes of pairs 1-11, in sequence,for pairs 67-77.
- Attributes
Attributes
Environmental Properties
Temperature Rating (Range)-20°C to +105°C
General Information
ManufacturerSeacoast
Design & Construction
Conductor MaterialTin-Coated Copper
Conductor Count120
Jacket MaterialCross-Linked Polyvinylidene Flouride (PVDF)
Cable Diameter Max (in)0.802
Solid/StrandedStranded
Stranding7
Shielded/UnshieldedOverall Shielded
Shield TypeTin-Coated Copper Braid
Cable Diameter Min (in)0.744
Electrical Properties
Insulation MaterialCross-Linked Polyalkene
Voltage Rating600V
Physical Properties
Bend Radius (in)10.5
Weight per Foot0.485