LS3SWU44

LS3SWU7

Spec #:M24643/36-09UN

MFR #:M24643/36-09UN

GCG #:LS3SWU44

Spec #:M24643/36-09UN

MFR #:M24643/36-09UN

GCG #:LS3SWU44

Min Qty:1

  |  

Qty Increment:1

Seacoast USA's M24643/36-09UN (LS3SWU44) is a 600V watertight cable with non-flexing service. M24643/36-09UN has 132 18 AWG conductors with a minimum diameter of 2.14 and a maximum diameter of 2.24 inches. LS3SWU44 has a bend radius of 13 inches, and is Individually & Overall Shielded with Thermoset insulation material and a Cross-Linked Polyolefin external jacket, operating from -20°C to +90°C. Stranded coated or uncoated copper conductor, thermoset insulation, three conductors (white-black-red) cabled to form triad, optional binder tape, braided tinned copper shielded, shielded insulation of two sealed Polyester tapes or one tape with extruded jacket. Standard Identification Code by Method 2. The required number of shielded triads cabled consecutively, fillers, binder tape. Cross-linked Polyolefin jacket.
Requires Quote

Min Qty:1

  |  

Qty Increment:1

Seacoast USA's M24643/36-09UN (LS3SWU44) is a 600V watertight cable with non-flexing service. M24643/36-09UN has 132 18 AWG conductors with a minimum diameter of 2.14 and a maximum diameter of 2.24 inches. LS3SWU44 has a bend radius of 13 inches, and is Individually & Overall Shielded with Thermoset insulation material and a Cross-Linked Polyolefin external jacket, operating from -20°C to +90°C. Stranded coated or uncoated copper conductor, thermoset insulation, three conductors (white-black-red) cabled to form triad, optional binder tape, braided tinned copper shielded, shielded insulation of two sealed Polyester tapes or one tape with extruded jacket. Standard Identification Code by Method 2. The required number of shielded triads cabled consecutively, fillers, binder tape. Cross-linked Polyolefin jacket.

Attributes

Environmental Properties
Temperature Rating (Range)-20°C to +90°C
General Information
ManufacturerSeacoast
Design & Construction
Conductor Count132
Jacket MaterialCross-Linked Polyolefin
Cable Diameter Max (in)2.24
Solid/StrandedStranded
Shielded/UnshieldedIndividually & Overall Shielded
Cable Diameter Min (in)2.14
Electrical Properties
Insulation MaterialThermoset
Voltage Rating600V
Physical Properties
Bend Radius (in)13
Weight per Foot3.278